iBodyinfo 8-Electrode 4-Frequency BIA Module BCM-MF570
A medical-grade 8-electrode 4-frequency BIA module for professional devices with stringent accuracy demands. Its core is an objective algorithm paired with 4-frequency technology, enabling your product to deliver clinical-grade data analysis.
Get Datasheet & Custom Quote
Please provide your details, and our will contact you within one business day with the complete product datasheet, an integration plan, and a formal quotation.
Product Introduction
The iBodyinfo BCM-MF570 is a professional 8-electrode quad-frequency BIA module, engineered for medical-grade body composition analyzers and high-end scientific instruments. Consequently, it represents the pinnacle of iBodyinfo’s expertise in multi-frequency bioelectrical impedance analysis (BIA).
Body composition analyzer module
We offer a complete, turnkey measurement solution with a state-of-the-art algorithm. In short, it’s designed for the most demanding applications where precision is paramount.
Core Advantages
Objective Algorithm, Free from Empirical Estimates: This is the cornerstone of our technology. The BCM-MF570’s algorithm calculates body composition without empirical inputs like age or gender. As a result, it ensures scientifically pure, unbiased results across diverse patient populations and body types.
Direct Segmental Multi-Frequency Measurement (DSM-BIA): As an advanced 8-electrode segmental BIA module, it independently analyzes five body segments (four limbs and trunk). This method provides a robust foundation for detailed segmental muscle/fat analysis. Furthermore, it is essential for localized diagnostics.
Professional-Grade 4-Frequency Accuracy: By measuring at four key frequencies (5/50/250/500KHz), it can precisely differentiate between intracellular and extracellular water, significantly enhancing the accuracy of body water analysis and other core metrics beyond dual-frequency modules.
Comprehensive Health Insights: Outputs over 20 core and research-grade metrics, including segmental analysis of muscle, fat, and water, ECW/TBW ratios, and VFL, enabling your device to provide a truly comprehensive clinical report.
Technical Highlights
Measurement Method: 8-Electrode, High-Performance 4-Frequency (5/50/250/500KHz) BIA
Interface: Open-protocol 3-wire TTL serial port (RS232 optional) for streamlined system integration.
Firmware Maintenance: Supports the standard Ymodem protocol for remote updates, ensuring long-term device relevance.
Reliability: Features high-level ESD protection and an integrated ultrasonic ranging port for robust performance in professional environments.
Applicable Scenarios
Professional medical-grade body composition analyzers in hospitals and clinics.
Scientific research projects in universities and institutions.
High-end wellness centers and professional health management clinics.
Commercial devices requiring the highest level of data accuracy and dimensionality.
Partnership Commitment
We are more than just a supplier; we are your strategic partner. As a leading provider of body composition analyzer module technology, we are committed to your success. Therefore, our support for your medical-grade BIA solution is truly end-to-end. This partnership covers everything from core components to full OEM/ODM services. Ultimately, we ensure your product meets the most rigorous standards.
The following are the detailed technical specifications for the iBodyinfo BCM-MF570 module. All parameters are rigorously tested to provide precise data for your project evaluation and system integration.
Measurement Principle & Core Performance
Parameter | Specification |
Analytical Model | 5-Segment Cylindrical Model (Limbs & Trunk) |
Core Technology | Direct Segmental Multi-Frequency BIA (DSM-BIA) with an objective algorithm, free from empirical formulas |
Electrode Method | 8-electrode, 8-point tactile electrode |
Measurement Frequencies | Quad-Frequency (5kHz, 50kHz, 250kHz, 500kHz) |
Measurement Time | < 20 seconds |
Measurement Current | 200μA (±10μA) |
Data Output Capabilities
The BCM-MF570 module provides a comprehensive suite of professional-grade health metrics, with key categories and items as follows:
- Fundamental Composition Analysis
- Body Composition Analysis (Total Body Water, Protein, Minerals, Body Fat Mass)
- Muscle-Fat Analysis (Weight, Skeletal Muscle Mass, Body Fat Mass)
- Obesity Diagnostics (BMI, Percent Body Fat, Obesity Degree)
- Core Segmental & Body Water Analysis (Quad-Frequency Advantage)
- Segmental Muscle Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg)
- Segmental Fat Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg)
- Segmental Water Analysis (Right Arm, Left Arm, Trunk, Right Leg, Left Leg)
- Intracellular/Extracellular Water & Segmental Extracellular Water Analysis
- ECW/TBW Ratio
- Advanced Health & Research Metrics
- Basal Metabolic Rate (BMR), Body Cell Mass (BCM), Bone Mineral Content (BMC)
- Visceral Fat Level (VFL), Visceral Fat Area (VFA), Waist-Hip Ratio (WHR)
- Body Balance Assessment (Upper, Lower, Upper-Lower)
- Fat-Free Mass Index (FFMI), Fat Mass Index (FMI)
- Raw Impedance Values (per segment & frequency)
Hardware, Physical & Environmental Parameters
Parameter | Specification |
Power Supply | DC 5V, 500mA |
Communication Interface | 3-wire TTL Serial Port (RS232 optional) |
Internal Expansion Interfaces | • 4-wire Load Cell Interface • 8-Electrode Interface • Ultrasonic Ranging Interface |
Module Dimensions (W x L x T) | 52 x 54 x 1.6 mm |
Operating Environment | Temperature: -10 to 70 °C Humidity: 30 to 75% RH Pressure: 70 to 106 kPa |
Storage Environment | Temperature: -20 to 120 °C Humidity: 10 to 95% RH (non-condensing) Pressure: 50 to 106 kPa |
Note: In the interest of continuous product improvement, specifications are subject to change without prior notice.
Ultrasonic Height Measurement Module
Add automatic height measurement to your device for a fully integrated user experience. This module has been rigorously tested by our team and connects seamlessly to the dedicated interface on our BIA measurement modules. No additional driver development or compatibility debugging is required, ensuring stable, out-of-the-box performance. This significantly enhances the professionalism and value proposition of your end-product.
High-Precision Load Cell
Accurate weight is the fundamental baseline for all bioelectrical impedance analysis (BIA). We offer a selection of pre-verified, high-precision load cells capable of delivering up to 10g measurement precision. They are guaranteed to be fully compatible with the weighing interface on our measurement modules. By choosing our recommended sensor, you bypass the complex process of component selection, validation, and debugging, ensuring your system's high reliability right from the source.